Title: | Test Retest Reliability of Ocular Vestibular Evoked Myogenic Potentials · |
Authors: | Singh, Niraj Kumar Sarda, Sharada Sinha, Sachidanand Shivajirao, Tamsekar Sulochana |
Keywords: | Otolithfanctions;SCM Muscle;cVEMP |
Issue Date: | 2011 |
Journal Name: | Journal of All India institute of Speech and Hearing |
Volume No.: | 30 |
Pages: | 207-210 |
Abstract: | Occular Vestibular Evoked Myogenic Potentials (oVEMP) responses have been consistently obtained in healthy individuals. Reports in literat11re have been suggestive of their utility in evaluating patients with vestibular disorders (Iwasaki et al., 2008 & 2009). Compared to Cervical VEMPs (cVEM PS}, o VEMPs are less strenuous for the subjects to perform, and symmetrical responses can be easily obtained without monitoring background activation. As the oVEMP test gains popularity and worldvide recognition as a valid and reliable test of otolit/1 function, it is likely to supplement cVEMP in the assessment of end organ function and act as a complementory technique when assessing central vestibular disorders. However, the clinical use of any test requires the establishment of reliability of the test and little is known about the test-retest reliability of oVEMPs (Isaradisaikul, Strong, Moushey, et al., 2008; Eleftheriadou, Deftereos, Zarikas, et al., 2008). Nguyen et al., (2010) reported about the test-retest reliability of oVEMP , lwweve1 smaller number of participants, larger gap between test and retest sessions and absence of fixed reference point for upward gaze may have played spoilsport and a better control at these variables may bring about a different res11lt. So, the present study aimed at examining the test-retest reliability of the sound-induced oVEMP parameters. Monaural contralateral oVEMPS were recorded from 30 healthy individuals with normal audio-vestibular system and the test was repeated after a minimum gap of 1 week, keeping the other parameters constant. The obtained data was analyzed using Cronbach 's alpha test. The results revealed excellent test-retest reliability for the amplitude parameters barring the asymmetry ratio, which showed fair-to-moderate reliability. The latencies also demonstrated fair-to-moderate test-retest reliability. These reliability values for oVEMP are better than those reported for cVEMP and could be attributed to a number of factors including smaller area of electrode placement making it less error prone, oVEMP being excitatory potential as opposed to cVEMP being inhibitory, and lesser fatigability of extra-occular muscles contrary to higher fatigability of the SCM muscle. The test-retest reliability values, thus, prove that the test is quite reliable and can be used clinically with confidence. |
URI: | http://203.129.241.91:8080//handle/123456789/2015 |
ISSN: | 0973-662X |
Appears in Resource: | Journal Articles |
File | Description | Size | Format | |
---|---|---|---|---|
207to210.pdf | 606.38 kB | Adobe PDF | View/Open |
Items in Database are protected by copyright, with all rights reserved, unless otherwise indicated.