Skip navigation
Indian Literature Database on Communication Disorders

Indian Literature Database
on Communication Disorders

Smiley face


Home


Categories &
Resource Types


Author


Title


Year


Subject


Login/Register

Please use this identifier to cite or link to this item: http://localhost:8080//handle/123456789/2012
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKaur, Ramandeep-
dc.contributor.authorGanesh, A C-
dc.contributor.authorSubba Rao, T A-
dc.date.accessioned2020-12-03T11:53:20Z-
dc.date.available2020-12-03T11:53:20Z-
dc.date.issued2011-
dc.identifier.issn0973-662X-
dc.identifier.urihttp://203.129.241.91:8080//handle/123456789/2012-
dc.description.abstractPerception of speech is an important goal for persons with Cochlear Implant ( CI) and Electro Acoustic Stimulation (EAS). It has been argued that naturally produced clear speech is more intelligible to such persons than conversational speech. The factors responsible for clear speech advantage are increased voice intensity slower rate, frequent pauses, greater vowel duration. and dynamic formant movements. The relative-advantage of clear speech in CI and EAS are not yet well understood. The present study used 20 native Hindi Speaking .( age range 20-30,years) participants on a listening task. The stimuli were 90 previously selected Hindi sentences processed with a . noise band vocoder implemented in Matlab. The sentences were spoken by a native Hindi speaker which was recorded in both Clear and Conversational speaking styles & mixed with four talker babble at -4 dB SNR. CI processing simulated using 8-clzannel noise-band vocoder. The sentences were filtered to 8 bands and the envelopes were extracted from each band. The carrier noise bands were modulated by the envelopes and resynthesized to produce the processed speech. Simulation of EAS was achieved with low pass stimulus (630Hz) and upper five channels of the eight-channel vocoder. Verbatim responses of the subjects were recorded and scored for accuracy. The overall results indicated better understanding in clear speaking style than in conversational style, in simulated CI condition as well as simulated EAS condition. The data was consistent with previous studies. Clear speech lzad an advantage in improving speech perception whenever there were/ewer cues for speech perception due to noise in CI and EAS. The details of comparison of CI and EAS conditions will be discussed.en_US
dc.language.isoenen_US
dc.subjectCochlear Implanten_US
dc.subjectElectro Acoustic Stimulationen_US
dc.titleClear and Conversation Speech perception in simulated Cochlear Implant and Simulated Electro Acoustic Stimulationen_US
dc.typeArticleen_US
dc.journalname.journalnameJournal of All India institute of Speech and Hearingen_US
dc.volumeno.volumeno30en_US
dc.pages.pages189-194en_US
Appears in Resource:Journal Articles

Files in This Item:
File Description SizeFormat 
189to194.pdf964.14 kBAdobe PDFView/Open
Show simple item record


Items in Database are protected by copyright, with all rights reserved, unless otherwise indicated.