Skip navigation
Indian Literature Database on Communication Disorders

Indian Literature Database
on Communication Disorders

Smiley face


Home


Categories &
Resource Types


Author


Title


Year


Subject


Login/Register

Please use this identifier to cite or link to this item: http://localhost:8080//handle/123456789/1826
Title: Comparison of Nasalance Values obtained from Nasality Visualization System and Nasometer II
Authors: Madhu Sudarshan Reddy, B
Sheela, S
Pebbili, Gopi Kishore
Keywords: Nasalance;Nasometer;Nasality
Issue Date: 2012
Journal Name: Journal of All India Institute of Speech and Hearing
Volume No.: 31
Pages: 1-9
Abstract: This study was designed to compare nasalance scores obtained with the Nasality visualization system (NVS) and Nasometer II (NM), and to evaluate test-retest reliability of nasalance scores on each of these instruments. Twenty two adult females, without any resonance or articulation disorders, in the age range of 17 to 25 years were considered for the study. Nasalance values were obtained using NVS and NM for the stimuli vowels (/a/, i// and /u/), syllables (/pa/, /ta/, /ka/, /ba/, /da/ and /ga/), eight oral and eight nasal sentences. Following familiarization task, the participants were instructed to read the stimuli with the headset/separator handle for the actual recording. Results indicated trends of increase in nasalance values with increase in vowel height, place of articulation moving backward in the oral tract, and voicing. Paired sample t test revealed significant difference between the nasalance measured by NVS and NM instruments across all the stimuli at p < 0.05 level of significance. Chronbach’s alpha revealed good test retest reliability for both NVS and NM for most of the stimuli (α > 0.70). From the findings of the study it may be concluded that nasalance values obtained from the Nasometer II and Nasal visualization system are not interchangeable and cannot be compared directly. The normative data, cutoff scores, sensitivity, specificity and other data of NM might not be applicable to nasalance values obtained from NVS and therefore, has to be established separately for NVS. Good test retest reliability obtained in the present study for NVS makes it a reliable nasalance measuring tool for clinical and research purposes. However, further studies investigating diagnostic efficacy using clinical population and correlations of perceptual analysis of nasalance might verify the validity of this instrument.
URI: http://203.129.241.91:8080//handle/123456789/1826
ISSN: 0973-662X
Appears in Resource:Journal Articles

Files in This Item:
File Description SizeFormat 
Comparison of Nasalance Values obtained from Nasality Visualization System and Nasometer II.pdf286.61 kBAdobe PDFView/Open
Show full item record


Items in Database are protected by copyright, with all rights reserved, unless otherwise indicated.